1.Construction of 0.6/1kv abc cable
Phase conductors are concentrically stranded EC Grade aluminum wires, insulated with either black weather resistant cross linked polyethylene (XLPE) or polyethylene (PE). The conductor insulation is marked with longitudinal ridges for phase identification.
Neutral messengers are concentrically stranded AAC or 6201 Alloy or ACSR. Neutral messenger can either be bare or insulated, depending on ABC aerial cable design.
2.Standardsof 0.6/1kv abc cable
BS7870, HD626, NF33, IEC228, IEC209, IEC60502
3.Application of 0.6/1kv abc cable
New type of Aerial Bundle Cable for Power transmission, used for rebuilding of urban and forest regions, which can improve safety and reliance of electrified wire netting.
0.6/1kv abc cable | |||||||
SPEC. mm2 | Conductor Structure | Insulation Material | Insulation Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Weight (kg/km) | Packing Meters per Drum | |
Phase (Compacted AL) | Neutral(Alloy) | ||||||
(No./mm) | Aluminum (No./mm) | ||||||
1x16+1x16 | 7/1.72 | 7x1.72 | XLPE (HDPE) | 1.2 | 12.5 | 110.1 | 250-4000m |
1x25+1x25 | 7/2.15 | 7/2.15 | 1.2 | 14.9 | 163.9 | 250-4000m | |
1x35+1x35 | 7/2.54 | 7/2.54 | 1.4 | 17.5 | 229.0 | 250-3500m | |
1x50+1x50 | 7/2.92 | 7/2.92 | 1.4 | 20.1 | 300.0 | 250-3000m | |
1x70+1x70 | 19/2.15 | 19/2.15 | 1.4 | 23.6 | 423.2 | 250-3000m | |
1x95+1x95 | 19/2.54 | 19/2.54 | 1.6 | 27.6 | 585.4 | 250-3000m | |
2x16+1x16 | 7/1.72 | 7/1.72 | 1.2 | 14.2 | 175.8 | 250-4000m | |
2x25+1x25 | 7/2.15 | 7/2.15 | 1.2 | 16.7 | 258.4 | 250-3500m | |
2x35+1x35 | 7/2.54 | 7/2.54 | 1.4 | 19.7 | 361.2 | 250-3500m | |
2x50+1x50 | 7/2.92 | 7/2.92 | 1.4 | 22.5 | 472.1 | 250-3000m | |
2x70+1x70 | 19/2.15 | 19/2.15 | 1.4 | 26.1 | 658.3 | 250-3000m | |
2x95+1x95 | 19/2.54 | 19/2.54 | 1.6 | 30.5 | 908.2 | 250-3000m | |
3x16+1x16 | 7/1.72 | 7/1.72 | 1.2 | 16.3 | 241.5 | 250-3500m | |
3x25+1x25 | 7/2.15 | 7/2.15 | 1.2 | 19.1 | 353.6 | 250-3500m | |
3x35+1x35 | 7/2.54 | 7/2.54 | 1.4 | 22.5 | 493.5 | 250-3000m | |
3x50+1x50 | 7/2.92 | 7/2.94 | 1.4 | 25.7 | 644.1 | 250-3000m | |
3x70+1x70 | 19/2.15 | 19/2.15 | 1.4 | 29.7 | 895.2 | 250-3000m | |
3x95+1x95 | 19/2.54 | 19/2.54 | 1.6 | 34.6 | 1233.5 | 250-3000m |
0.6/1kv abc cable | ||||||
SPEC. mm2 | Conductor Structure (Compacted AL) (No./mm) | Insulation Material | Insulation Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Weight (kg/km) | Packing Meters per Drum |
2x16 | 7/1.72 | XLPE (HDPE) | 1.2 | 14.6 | 131.4 | 250-4000m |
2x25 | 7/2.15 | 1.2 | 16.8 | 189.0 | 250-4000m | |
2x35 | 7/2.54 | 1.4 | 19.8 | 264.5 | 250-3500m | |
2x50 | 7/2.92 | 1.4 | 22.6 | 344.1 | 250-3000m | |
2x70 | 19/2.15 | 1.4 | 25.6 | 470.0 | 250-3000m | |
2x95 | 19/2.54 | 1.6 | 29.8 | 645.5 | 250-3000m | |
3x16 | 7/1.72 | 1.2 | 15.7 | 197.1 | 250-4000m | |
3x25 | 7/2.15 | 1.2 | 18.1 | 283.5 | 250-3500m | |
3x35 | 7/2.54 | 1.4 | 21.3 | 396.7 | 250-3500m | |
3x50 | 7/2.92 | 1.4 | 24.3 | 516.2 | 250-3000m | |
3x70 | 19/2.15 | 1.4 | 27.6 | 705.1 | 250-3000m | |
3x95 | 19/2.54 | 1.6 | 32.1 | 968.2 | 250-3000m | |
4x16 | 7/1.72 | 1.2 | 17.6 | 262.9 | 250-3500m | |
4x25 | 7/2.15 | 1.2 | 20.3 | 378.0 | 250-3500m | |
4x35 | 7/2.54 | 1.4 | 23.9 | 528.9 | 250-3000m | |
4x50 | 7/2.92 | 1.4 | 27.3 | 688.3 | 250-3000m | |
4x70 | 19/2.15 | 1.4 | 30.9 | 940.1 | 250-3000m | |
4x95 | 19/2.54 | 1.6 | 36.0 | 1291.0 | 250-3000m |