Overhead AAC/AAAC/ACSR/ACAR Aluminum Conductor Electrical Cable

Overhead AAC/AAAC/ACSR/ACAR Bare Conductor Electrical Cable Size AAAC cable
1.All Aluminum-Alloy Conductors (AAAC) is a concentric-lay-stranded conductor consisting of aluminum-alloy wires available in both single layer and multi-layer constructions.
2.All Aluminum-Alloy Conductors (AAAC) can be used in Medium, High and Extra-High voltage transmission lines
3.AAAC offers better sag performance due to the high strength-to-weight ratio provided by the aluminum-alloy.
4.In addition, AAAC provides a higher corrosion resistance than ACSR conductors. Application of AAAC Cable.
Chat Now

Product Details


Application:

The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium 1350 and insulated with XLPE. Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation as overhead power lines up to 1000 V incl.

Packaging & Delivery

  • wooden drum/steel wooden drum/steel iron drum for Acsr Wire,Acsr Wire Cable,Acsr Bare Conductor

  • Delivery Time:15-20 working days

    IMG_20160324_105649_副本22.jpg

Package:

  • In coils, wooden drums, steel drums or steel-wooden drums.

  • We could producing according to the customers' requirements.Welcome your request for any quotations!

IMG_8316.JPG

Company Information

Shandong New Luxing Cable Co.,Ltd established in the year of 1999, The headquarter is located in Jinan City, the capital of Shandong province, Registered capital of USD16.5 million, Legal representative Wang Xiuzhen. Our factory is located in Linyi Economic Development ZoneCovering an area of more than 60 acres.IMG_8164.JPG{KQZCN8AQ{W0)D$B[Y~OG{3.png



ABC005.jpg

ABC011.jpg

ABC012.jpgIMG_8164.JPG

工厂设备.png


Standard

BS 7870-5:1999

Construction

Conductor (for either phase, neutral or street lighting)

The conductors shall be of aluminium 1350 wires and are compacted circular stranded(RM).

Insulation

XLPE. 1, 2 and 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth.

Assembly

2 up to 4 cores of equal cross section are stranded together in left-hand lay, additionally 1 or 2 cores of reduced cross section can be co-stranded.

Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV

4

Laying temperature

°C

min. -20

Operating temperature

°C

-30 ~ +80

Conductor temperature

°C

max. +80

Short-circuit temperature

°C/s

max. +130 /5

Bending radius (min.)


18 × o of cable


Hot Tags: overhead AAC/AAAC/ACSR/ACAR aluminum conductor electrical cable, China, manufacturers, factory, sizes, price, for sale

Inquiry