Power Cable, 5 Kv, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

Power Cable, 5 Kv, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

Product Description MV-105, Power Cable, 5 KV, 3/C, Cu/EPR/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072) Features UL Listed as MV-105. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends. Application Primary power...
Chat Now

Product Details

Product Description

Power Cable, 5 Kv, 3/C, Cu/Epr/Cts/CPE (ICEA S-93-639/NEMA WC71/UL 1072)

Features
UL Listed as MV-105. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application
Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry
locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.

Standards
UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV - 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV - 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV- 46 kV.

Specifications
Maximum operating voltage: 5 kV to 25 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations, Normal: 105°C, Emergency: 140°C, Short Circuit: 250°C

Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset ethylene propylene rubber (EPR). On request, Amorphous EPR.
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed tinned copper tape, 5 mil thick, 25% minimum overlap.
6. Grounding (Optional): One or three tinned copper or covered conductors cabled with phase conductors.
7. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
8. Jacket: Black sunlight resistance and flame retardant chlorinated polyethylene (CPE) compound

cable007.jpg

alloy cables_.jpg  .


100% and 133% Insulation Levels (90 mil)
SizeNumber of StrandsConductor NominalJacket ThicknessApproximate Outside DiameterApproximate Net Weight
CopperAluminum
AWG of kcmil
inmilinlb/kft
870.13801.2810-
670.17801.27990816
470.21801.371218941
270.27801.4915561115
1190.3801.5518151260
1/0190.34801.6320941393
2/0190.381101.7925571674
3/0190.421101.8930171902
4/0190.48110235482144
250370.521102.1340722411
300370.571102.2346572665
350370.621102.3352432917
400370.661102.4258613205
500370.741102.6470913771
600610.811402.984624475
750610.911403.11101325155
1000611.061403.43129866352


packing  shipping_.jpg

Hot Tags: power cable, 5 kv, 3/c, cu/epr/cts/cpe (icea s-93-639/nema wc71/ul 1072), China, manufacturers, factory, sizes, price, for sale